Accuracy of Blood Glucose Levels Between Commercial Control Serums High Abnormal Levels of Brands A and Brands B


Ikke Nanda Amalia(1), Anik Handayati(2), Andreas Putro Ragil Santoso(1)

Program Studi D-IV Analis Kesehatan, Fakultas Kesehatan
Universitas Nahdlatul Ulama Surabaya
Email: ikkenandamalia@gmail.com

ABSTRACT
Clinical laboratory must be guarantee of accuracy and precision on the result laboratory examination, that is quality of laboratory test has really guaranteed. The quality of good laboratory examination is really depend on the quality assurance program being udertaken, one of them is measurement value of accuracy using control sera. The differences between of the laboratory test result with target value of control sera is an innacurate indicator of laboratory test. The purpose of this study was to measure the differences of the value accuracy blood glucose levels between commercial control sera abnormally high level of brand A and B. The kind of this study was observational analit method using longitudinal research approach. The samples were commercial control sera abnormally high level brand A and B which measured accuracy through blood glucose examination. The result showed that commercial control sera abnormally high level of brand A has an average value of accuracy is 3,734% while brand B is 7,682%. The result of analysis using Mann-Whitney test showed that p value 0,001 that’s meaning p<α and H_0 is rejected. There is differences of the value accuracy blood glucose levels between commercial control sera abnormally high level of brand A and B.

Keywords: control sera, accuracy, blood glucose levels




Program Studi D-IV Analis Kesehatan, Fakultas Kesehatan, Universitas Nahdlatul Ulama Surabaya.
Jurusan Analis Kesehatan, Politeknik Kesehatan Kementerian Kesehatan Surabaya

Article Details

References

  1. REFERENSI
  2. 1. Pertiwi, D. 2010. Pemantapan Mutu Laboratorium Bidang Kimia Klinik. Majalah Sultan Agung, 48 (122): 17-31.
  3. 2. Setiawan, S.F. 2016. Hasil Pemantapan Mutu Internal Pada Alat Automated Chemistry Analyzer Untuk Pemeriksaan Kolesterol Total Darah Di Laboratorium Klinik RSUD Ciamis. Tidak Dipublikasikan. Karya Tulis Ilmiah. Ciamis: Program Studi D3 Analis Kesehatan Sekolah Tinggi Ilmu Kesehatan Muhammadiyah Ciamis.
  4. 3. Sukorini, U. 2010. Pemantapan Mutu Internal Laboratorium. Yogyakarta: Alfamedia.
  5. 4. Departemen Kesehatan. 2013. Cara Penyelenggaraan Laboratorium Klinik Yang Baik. Peraturan Menteri Kesehatan Republik Indonesia Nomor 43 Tahun 2013. Jakarta: Kementerian Kesehatan.
  6. 5. Lestari, S.M. 2015. Quality Control Laboratorium Klinik. http://semar-septi.blogspot.co.id/2015/09/quality-control-qc-laboratorium-klinik.html. [12 Desember 2017].
  7. 6. Subiyono, Martsiningsih, M.A., dan Gabrela, D. 2016. Gambaran Kadar Glukosa Darah Metode GOD-PAP (Glucose-Oxidase-Peroxidase Aminoantipyrine) Sampel Serum dan Plasma EDTA (Ethylene Diamine Tetra Acetat). Teknolab Jurnal, 5 (1): 45-48.